Repository of Research and Investigative Information

Repository of Research and Investigative Information

Ilam University of Medical Sciences

Effect of a Non-Ionic Surfactant on Xylene Removal in a Scoria-Compost-Based Biofilter

Sun Nov 17 22:59:12 2024

(2016) Effect of a Non-Ionic Surfactant on Xylene Removal in a Scoria-Compost-Based Biofilter. Clean-Soil Air Water. pp. 1759-1765. ISSN 1863-0650

Full text not available from this repository.

Official URL: http://apps.webofknowledge.com/InboundService.do?F...

Abstract

The effect of a non-ionic surfactant, Tween-20, on xylene removal performance of a previously acclimated scoria-compost-based biofilter was evaluated. In the presence of the surfactant, the maximum elimination capacities (ECmax) of 71.0, 84.1, and 93.6 gm(-3) h(-1) were obtained for xylene inlet loading rates (ILRs) of 114.9, 124.1, and 197.1 gm(-3) h(-1) at empty bed residence times (EBRTs) of 40, 60, and 90 s, respectively. When the biofilter was fed the nutrient solution with Tween-20, the average removal efficiency (REavg) was increased approximately 13 and 14 at EBRTs of 40 s (ILRavg of 43-47 gm(-3) h(-1)) and 60 s (ILRavg of 61 gm(-3) h(-1)), respectively. This indicates that the surfactant improved the performance of the biofilter at moderate ILRs. However, the removal of xylene was not significantly affected by the surfactant at high ILRs, around which ECmax was achieved. This means that the non-ionic surfactant probably had a positive effect on the biofiltration of xylene when the diffusion through the biofilm, rather than biodegradation rates, appears to be the main process governing the performance of biofilter. Overall, this study showed that Tween-20, in terms of xylene removal efficiency, may not have similar effects on the performance of biofilter at various loading conditions.

Item Type: Article
Creators:
CreatorsEmail
Amin, M. M.UNSPECIFIED
Rahimi, A.UNSPECIFIED
Bina, B.UNSPECIFIED
Moghadam, F. M.UNSPECIFIED
Nourmoradi, H.UNSPECIFIED
Heidari, M.UNSPECIFIED
Keywords: Biofiltration Tween-20 Volatile monocyclic hydrocarbons gas-flow rate biotrickling filters operational parameters inlet concentration biofiltration performance toluene vapors bioreactor streams Science & Technology - Other Topics Environmental Sciences & Ecology Marine & Freshwater Biology Water Resources
Divisions:
Page Range: pp. 1759-1765
Journal or Publication Title: Clean-Soil Air Water
Journal Index: ISI
Volume: 44
Number: 12
Identification Number: https://doi.org/10.1002/clen.201500415
ISSN: 1863-0650
Depositing User: مهندس مهدی شریفی
URI: http://eprints.medilam.ac.ir/id/eprint/403

Actions (login required)

View Item View Item