Repository of Research and Investigative Information

Repository of Research and Investigative Information

Ilam University of Medical Sciences

Needle-trap device packed with the MIL-100(Fe) metal-organic framework for the extraction of the airborne organochlorine pesticides

Fri Apr 19 06:28:39 2024

(2021) Needle-trap device packed with the MIL-100(Fe) metal-organic framework for the extraction of the airborne organochlorine pesticides. Microchemical Journal. p. 7. ISSN 0026-265X

Full text not available from this repository.

Official URL: http://apps.webofknowledge.com/InboundService.do?F...

Abstract

This study was presented the development of the needle trap device (NTD) packed with the MIL-100(Fe) metal-organic framework (MOF) for extraction of organochlorine pesticides (Hexachlorobenzene, Aldrin, AlphaChlordane, Dildrin and DDT isomers) from the air environment for the first time. Specifications of synthesized MIL-100(Fe) were identified by Fourier-transfer infrared spectroscopy (FT-IR), X-ray Diffraction (XRD), field emission scanning electron microscopy (FE-SEM), energy dispersive spectroscopy (EDS) and elemental mapping techniques. The optimization of sampling and desorption parameters such as humidity, time, and temperature were performed by response surface methodology (RSM). Sampling and analysis of organochlorine pesticides were accomplished under different conditions in the laboratory scale and then was employed in the field study for the real air samples. The highest response was obtained at desorption temperature of 280 degrees C and desorption time of 5 min. The temperature and humidity of the sampling site were set to 30 degrees C and 25. Furthermore, the Limit of Detection (LOD) and Limit of Quantification (LOQ) for the targeted analytes were determined in the range of 0.04-0.41 mu g/m(3) and 0.21-1.82 mu g/m(3), respectively. Moreover, from the recovery standpoint, any significant change was not detected on the analytes after 6 days of storage at 4 degrees C. Also, the results of this study showed a high correlation (R-2 = 0.9882) between the results of the proposed method with the standard NIOSH method. This study exhibited that the proposed MIL-100(Fe)@NTD method can be employed as an eco-friendly, reliable, sensitive, and efficient procedure for sampling and determination of the organochlorine pesticides compared to the standard NIOSH method.

Item Type: Article
Creators:
CreatorsEmail
Soury, S.UNSPECIFIED
Firoozichahak, A.UNSPECIFIED
Nematollahi, D.UNSPECIFIED
Alizadeh, S.UNSPECIFIED
Kakaei, H.UNSPECIFIED
Abbasi, A.UNSPECIFIED
Keywords: Air MIL-100(Fe) MOF Needle trap device Organochlorine pesticides polycyclic aromatic-hydrocarbons solid-phase microextraction efficient sorbent nanoparticles fabrication pollutants residues films spe air Chemistry
Divisions:
Page Range: p. 7
Journal or Publication Title: Microchemical Journal
Journal Index: ISI
Volume: 171
Identification Number: https://doi.org/10.1016/j.microc.2021.106866
ISSN: 0026-265X
Depositing User: مهندس مهدی شریفی
URI: http://eprints.medilam.ac.ir/id/eprint/3718

Actions (login required)

View Item View Item