Repository of Research and Investigative Information

Repository of Research and Investigative Information

Ilam University of Medical Sciences

Monte Carlo determination of dosimetric parameters of a new 125I brachytherapy source according to AAMP TG-43 (U1) protocol

Wed Apr 24 01:04:59 2024

(2016) Monte Carlo determination of dosimetric parameters of a new 125I brachytherapy source according to AAMP TG-43 (U1) protocol. Archives of Iranian Medicine. pp. 186-191. ISSN 10292977 (ISSN)

Full text not available from this repository.

Abstract

Background: 125I is one of the important sources frequently used in brachytherapy. Up to now, several different commercial models of this source type have been introduced to the clinical radiation oncology applications. Recently, a new source model, IrSeed-125, has been added to this list. The aim of the present study is to determine the dosimetric parameters of this new source model based on the recommendations of TG-43 (U1) protocol using Monte Carlo simulation. Methods: The dosimetric characteristics of Ir-125 including dose rate constant, radial dose function, 2D anisotropy function and 1D anisotropy function were determined inside liquid water using MCNPX code and compared to those of other commercially available iodine sources. Results: The dose rate constant of this new source was found to be 0.983+0.015 cGyh-1U-1 that was in good agreement with the TLD measured data (0.965 cGyh-1U-1). The 1D anisotropy function at 3, 5, and 7 cm radial distances were obtained as 0.954, 0.953 and 0.959, respectively. Conclusion: The results of this study showed that the dosimetric characteristics of this new brachytherapy source are comparable with those of other commercially available sources. Furthermore, the simulated parameters were in accordance with the previously measured ones. Therefore, the Monte Carlo calculated dosimetric parameters could be employed to obtain the dose distribution around this new brachytherapy source based on TG-43 (U1) protocol. © 2016, Academy of Medical Sciences of I.R. Iran. All rights reserved.

Item Type: Article
Creators:
CreatorsEmail
Baghani, H. R.UNSPECIFIED
Lohrabian, V.UNSPECIFIED
Aghamiri, M. R.UNSPECIFIED
Robatjazi, M.UNSPECIFIED
Keywords: Brachytherapy Dosimetric characteristics LrSeed-125 Monte carlo simulation TG-43 (U1) iodine 125 radioactive iodine anisotropy Article clinical protocol computer simulation diagnostic procedure dosimetry image analysis Monte Carlo method oncology quantitative analysis radioactivity radiodiagnosis thermoluminescence dosimetry comparative study human Neoplasms practice guideline procedures radiometry standards Humans Iodine Radioisotopes Practice Guidelines as Topic
Divisions:
Page Range: pp. 186-191
Journal or Publication Title: Archives of Iranian Medicine
Journal Index: Scopus
Volume: 19
Number: 3
ISSN: 10292977 (ISSN)
Depositing User: مهندس مهدی شریفی
URI: http://eprints.medilam.ac.ir/id/eprint/1369

Actions (login required)

View Item View Item